DUAL LAN ON A COMPUTER WHAT IS IT AND WHAT ARE THE

What is dual power supply for relay protection

What is dual power supply for relay protection

A self or dual-powered supply is often used in the design MCCBs or ACBs with an electric trip unit circuit. In this reference design the rectified input charges the capacitor to generate the output voltage. The regulated DC output voltage is set by a Zener Diode and a MOSFET shunt regulator. The 7SR46 dual powered protection relay is to be showcased at Enlit Europe, taking place in Frankfurt from November 29 to December 1. Due to their often remote location, secondary substations do not always have a battery to provide power to electronic equipment such as protection relays. Electronic trip units are true RMS sensing-over-current trip devices, requiring no external supply for their basic functioning.

Read More
What is a hot aisle in a computer room

What is a hot aisle in a computer room

The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. Assuming a computer room is configured in such a way that either is an option, hot aisle containment may be seen as the better option because it has some thermal efficiency and ride-through advantages. However, because every computer room is unique, there is no one definitive solution. The HAC system directs the upward airflow to an AC return system such as a drop-ceiling void. The system simply aligns server fronts (air intakes) toward a shared cold aisle, and backs (exhausts) toward a shared hot aisle. Cold Aisle: Rows of racks face each other, forming a corridor where cool air is directed.

Read More
What should be used to seal the cold aisle in the computer room

What should be used to seal the cold aisle in the computer room

The Cool Shield AirStrip is an expanding foam tape designed to prevent unwanted air loss from gaps in contained aisles, server rack rows and data center infrastructure. Strips can be used above or below containment panels, next to rack rails, under server cabinets or in gaps in raised flooring. While advanced cooling systems like chilled water plants and CRAH units play a major role, one of the most effective strategies is much simpler: controlling how air moves through the data hall. This method raises the temperature of the air returning to a Computer Room Air Con itioner (CRAC) unit, which allows the unit to operate more eficiently. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content).

Read More
What is the size of the cable trays in the computer room

What is the size of the cable trays in the computer room

What cable tray sizes are standard? Standard cable tray widths per IEC 61537 and manufacturers' ranges are typically 50, 75, 100, 150, 200, 225, 300, 400, 450, 500, 600, 750, 900, and 1000mm. In practice, cable tray dimensions are a system of interrelated measurements —width, depth, length, and material thickness—that directly affect cable fill compliance, heat dissipation, structural loading, and long-term expandability. Here in the UK, standard widths run from a slim 50mm for a handful of data runs right up to 900mm or more for the heavy-duty. The mechanical and electrical characteristics, tests, certifications, overall quality management, recommendations mentioned in this technical guide only apply to our own cable management ranges and cannot under any circumstances be transposed to si osure, overheating or. A tray that is too small will overheat and physically damage, and too large tray will drain the project budget.

Read More
What to do if the bottom of the network cabinet is loose

What to do if the bottom of the network cabinet is loose

Any way you can run the cables through the wall from the networking cabinet into the main cabinet to the right, and store all of your networking gear in there? Mount the router to the wall above wires door from the outside and drill some hole through the door for the cables. Network hardware failures can cause connectivity issues, slow performance, or complete network downtime. Faulty routers, switches, cables, or network interface cards (NICs) can disrupt communication, suitable to business interruptions and reduced productivity. For example, tangled patch cords, missing labels, loose slack, tight bends, and unclear cable paths can slow down routine work.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales)

+27 21 850 1234

🇪🇺

EU Manufacturing Center

+34 936 214 587

📍

Headquarters (Spain)

Avinguda de la Garriga 23, 08830 Sant Boi de Llobregat, Barcelona, Spain