ELECTROSTATIC MEMS MODELLING CONTROL AND APPLICATIONS

Requirements for electrostatic grounding terminals in distribution boxes

Requirements for electrostatic grounding terminals in distribution boxes

The general rule requires connecting the grounding terminal of a grounding-type receptacle and a metal box joined to an equipment grounding conductor employing an equipment bonding jumper sized per Table 250. This Grounding Standard describes the technical requirements for grounding the SEC Distribution Network installations. 8 kV) feeder outlets of HV / MV Substations down to SEC Customer interface including KWH-Meters and meter boxes. The topic of system grounding is extremely important, as it affects the susceptibility of the system to voltage transients, determines the types of loads the system can. During fault conditions, low impedance results in high fault current flow, causing overcurrent protective.

Read More
Electrostatic Variable Optical Attenuator

Electrostatic Variable Optical Attenuator

A Variable Optical Attenuator (VOA) is a controllable device used to reduce the optical power traveling through a fiber or free-space optical path. The optical fiber built into each device is single mode over the specified operating wavelength. We offer the industry's most extensive selection of fiber variable optical attenuators (VOAs), addressing all application scenarios with best-in-class performance and value. These operate by collecting and collimating light from an input fiber and then reflecting this light off of an ultra-stable and reliable, single-axis DiCon MEMS mirror.

Read More
MEMS Multimode Optical Switch

MEMS Multimode Optical Switch

This optical switch, leveraging the power of Micro-Electro-Mechanical System (MEMS) technology, provides channel selection capabilities between a single input fiber and up to 16 output fibers. Jointly developed with DiCon Fiberoptics, this laboratory-grade, high performance optical switch is optimized for use with EXFO LTB solutions and with software control via SCPI over Ethernet. Research, development and manufacturing testing of optical transceivers Multiple DUT testing Automated. Functional Block Diagram: 2 channel, 8 Channel, 12 Channel, 16 Channel, 64 Channel,DiCon's MEMS Multimode On-Of Optical Switch has one input and one output fiber and provides the ability to turn on or of the optical signal passing through it. These fiber optic switches are compact cylindrical devices driven by a direct analog voltage and are intended to be integrated into a.

Read More
Well control box not starting

Well control box not starting

One of the most common causes of control box issues is a problem with the power supply. Why Above Ground? Much cheaper than pulling pump! We service all major pump brands including Franklin Electric, Grundfos, Goulds (Xylem), and Sta-Rite (Pentair). Working with any well system component requires absolute adherence to electrical safety protocols due to the presence of high voltage.

Read More
Installation height of distribution box control switch

Installation height of distribution box control switch

The proper installation of a distribution box involves placing it at the right height to ensure safety and convenience. According to the "Code for Acceptance of Construction Quality of Building Electrical Engineering" GB50303-2002, the vertical distance between the bottom surface of the fixed stainless steel enclosure ip67 and the ground should be greater than 1. Both sources stipulate that socket outlets, switches and controls should be installed at a height between 450mm and 1200mm above the finished floor level. generally, this means it is a minimum of 450mm to the underside of an outlet and a maximum of 1200mm to the top of a switch or a control. VISUAL DEVICE NOT LESS THAN 90" TO TOP OR 6" BELOW CEILING, WHICH EVER IS HIGHER. Ensure safe placement: install in dry, accessible areas with good ventilation and at appropriate height (typically ~1.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales)

+27 21 850 1234

🇪🇺

EU Manufacturing Center

+34 936 214 587

📍

Headquarters (Spain)

Avinguda de la Garriga 23, 08830 Sant Boi de Llobregat, Barcelona, Spain