THE ''EX D'' PROTECTION METHOD THE FUNCTION OF THE CONDUIT

Fixing wire clips at the bottom of the distribution box

Fixing wire clips at the bottom of the distribution box

For plastic boxes, press down on the Box Doctor® clip aligning the center slot over the damaged hole. Disordered wires and improper fixing in plastic distribution box junction boxes are common causes of poor contact and short circuits. Switchgear cable clamps are used to secure single high and low voltage cables and also to fasten cables made of polyethylene Insulated cables ensure the stability of the cable on a flat surface or on a triangular iron.

Read More
What to do if the bottom of the network cabinet is loose

What to do if the bottom of the network cabinet is loose

Any way you can run the cables through the wall from the networking cabinet into the main cabinet to the right, and store all of your networking gear in there? Mount the router to the wall above wires door from the outside and drill some hole through the door for the cables. Network hardware failures can cause connectivity issues, slow performance, or complete network downtime. Faulty routers, switches, cables, or network interface cards (NICs) can disrupt communication, suitable to business interruptions and reduced productivity. For example, tangled patch cords, missing labels, loose slack, tight bends, and unclear cable paths can slow down routine work.

Read More
45-degree right-angle bend on the side of the cable tray

45-degree right-angle bend on the side of the cable tray

To create a 45-degree bend, cut the side rails to remove a segment calculated by the formula (Tan (22. Learn more How to make cable tray bend / Cable tray offset formula / cable tray 45 degree bendQueries Solved in This. By applying the following formula you can quickly find the size of cut out section that you need to cut out of the side of the cable tray, or gutter-type section to make that angle. Depends on the type of cable tray, you can buy 90° tray fittings or use a speed square with a straight edge and a grinder or skill saw to cut 45° cuts. WARNING : BE CAREFUL WHEN YOU CUT TRUNKING,THIS MAY CAUSE INJURIES FROM SHARP EDGES BY CUTTING THE TRUNKING.

Read More
Symmetrical Component Method for Relay Protection

Symmetrical Component Method for Relay Protection

The method of symmetrical components is used to simplify fault analysis by converting a three-phase unbalanced system into two sets of balanced phasors and a set of single-phase phasors, or symmetrical components. In oltage and current are more sensitive to electric faults compared to their phase-domain counterparts. For this reason, several protection relays operate on symmetrical components nd many. We must practice these techniques in order to fully understand and feel comfortable with them.

Read More
Microprocessor-based relay protection tester characteristic and function testing

Microprocessor-based relay protection tester characteristic and function testing

In order to verify the proper operation of complex multifunctional microprocessor-based protection devices (MPD) at their inspection, start-up after repairs, or during periodic tests, they should be tested for proper operation at several of the most critical preset. Since the basic function of a protection relay is to correctly function under abnormal. The first relays were Electromechanical (EM): machines with moving parts actuated by coils connected to current and voltage sources. These required regular testing, adjustments and maintenance to ensure continued functioning.