UNDERSTAND THE IMPORTANCE OF SMART RING MAIN UNIT RMU

How many optical fiber cables need to be connected to the ring main unit

How many optical fiber cables need to be connected to the ring main unit

In the optical fiber ring topology, two optical fiber cables are required. Minimum Fibre Cores in the fibre cable between any two buildings: Each switch connects back to the core of the network with 4 fibre cores (2 running clockwise, 2 running anti-clockwise). This circular arrangement creates a highly efficient, high-capacity network architecture with several notable advantages. My engineer is saying that this won't work, that there is a limit of approximately 17 devices in the ring.

Read More
Factors that make relay protection difficult to understand

Factors that make relay protection difficult to understand

Many important issues, such as coordination of settings, operating times, characteristics of relays, mutual coupling of lines, automatic reclosing, and use of communication channels, are examined. Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor. Relay protection is the discipline of designing schemes that detect faults, coordinate relays, and isolate equipment without outages. In industrial power systems, Protection relays are expected to operate with high precision, isolating faults while keeping healthy parts of the network energized. This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution.

Read More
How to understand the sensitivity of relay protection

How to understand the sensitivity of relay protection

The sensitivity of a relay is mentioned as a ratio of the minimum value of short circuit current to the minimum value of the quantity for the operation. Based on simple examples of the generator-transformer unit protection from symmetrical short circuits, it was shown that the sensitivity factor is not a sufficiently objective measure of sensitivity of the. For example, unselective protection operation during a medium voltage network fault will cause an outage for an unnecessarily large number of consumers. Relay protection is essential to ensure the stability, reliability, and safety of electrical power systems.

Read More
What to do if the bottom of the network cabinet is loose

What to do if the bottom of the network cabinet is loose

Any way you can run the cables through the wall from the networking cabinet into the main cabinet to the right, and store all of your networking gear in there? Mount the router to the wall above wires door from the outside and drill some hole through the door for the cables. Network hardware failures can cause connectivity issues, slow performance, or complete network downtime. Faulty routers, switches, cables, or network interface cards (NICs) can disrupt communication, suitable to business interruptions and reduced productivity. For example, tangled patch cords, missing labels, loose slack, tight bends, and unclear cable paths can slow down routine work.

Read More
Standard for Jumper Wiring in Distribution Boxes of Smart Buildings

Standard for Jumper Wiring in Distribution Boxes of Smart Buildings

In the United States, the standard is ANSI/TIA-568-C, also known as the Commercial Building Telecommunications Cabling Standard. By providing guidelines for installation, maintenance and testing to improve availability and reduce expenses associated with downtime, the telecommunications standards define cabling types, distances, connections, cable system architectures, cable termination standards, performance. System adapts readily based on temperature, air movement, and lighting requirements. Previous infrastructure in a traditional building typically entailed unique layouts and cabling media for Information Technology (IT) and Operational Technology (OT) systems. IT and OT groups were also historically divided, with little to no crossover of the systems that each managed.

Read More