WEAK CURRENT BOX – GONEO GLOBAL

Weak current relay protection

Weak current relay protection

Differential Relay: Compares currents at two points; operates when there is a difference (used in transformers and generators). We have three ways to tackle the rising protection challenges: fine-tune the present protective relays, enforce a better fault response of the sources, and use protection principles that are less dependent on the sources. Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. Special Functions in Power Transmission Line Protection Second Function: Weak Infeed (Echo) Protection This function ensures fast and coordinated tripping of transmission lines during faults when one terminal contributes very little or no fault current, such as in the following cases: 1️⃣ One.

Read More
Method for measuring the current of a distribution box with a multimeter

Method for measuring the current of a distribution box with a multimeter

To measure the current, select the DC/AC current function with the appropriate range. Finally, connect the multimeter in series with the circuit and observe the current . Current measurements are easy to make, but they are done in a slightly different. There are a number of methods you can use to measure current, but the simplest way to measure direct current (DC) is by using a digital multimeter A gap is made in the circuit and is connected to a digital multimeter (DMM) so that it becomes part of the circuit itself.

Read More
Residual current protection of the distribution box

Residual current protection of the distribution box

Residual current protection can detect and isolate the grounding (leakage) fault of low-voltage distribution networks in time, which is an essential technical measure to reduce electric shocks and fire accidents and improve power supply safety. A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral. An RCD, which stands for Residual Current Device, is also known as a Residual Current Breaker (RCB) or Residual Current Circuit Breaker (RCCB). It is a safety device designed to protect against electric shock and hazardous fires.

Read More
What is the power meter reading for weak light

What is the power meter reading for weak light

A typical OPM is linear from about 0 dBm (1 milli Watt) to about -50 dBm (10 nano Watt), although the display range may be larger. Above 0 dBm is considered "high power", and specially adapted units may measure up to nearly + 30 dBm ( 1 Watt). Irrespective of power meter specifications, testing below about -50 dBm tends to be sensitive to stray ambient light leaking into fibers or connectors. Fiber Optic Measurement Units: "dB" and "dBm" Whenever tests are performed on fiber optic networks, the results are displayed on a power meter, OLTS or OTDR readout in units of "dB. Power (dBm) = 10 × log10 (Power in mW) A small change in dBm means a big change in mW.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales)

+27 21 850 1234

🇪🇺

EU Manufacturing Center

+34 936 214 587

📍

Headquarters (Spain)

Avinguda de la Garriga 23, 08830 Sant Boi de Llobregat, Barcelona, Spain